Advanced Search

Show simple item record

dc.contributor.advisorAkşit, Ercan
dc.contributor.authorBozkurt, Hasan
dc.date.accessioned2024-09-05T08:27:01Z
dc.date.available2024-09-05T08:27:01Z
dc.date.issued2022en_US
dc.date.submitted2022
dc.identifier.citationBozkurt, H. (2022). Ekokardiyografi ile bakılan koroner sinüs çap ve akım parametrelerinin koroner arter hastalığı ve yaygınlığı ile ilişkisinin değerlendirilmesi. Yayımlanmamış tıpta uzmanlık tezi, Çanakkale Onsekiz Mart Üniversitesi, Çanakkale.en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12428/6096
dc.description.abstractAmaç: Koroner arter hastalığının tanısında transtorasik ekokardiyografi ile bakılan koroner sinüs çap ve akım parametrelerinin koroner arter hastalığının erken tanısındaki öneminin araştırılması Gereç ve Yöntem: Çalışmaya koroner anjiyografi (KAG) yapılan, 50 kontrol grubu ve 50 vaka grubu olmak üzere toplam 100 hasta dahil edildi. Kontrol grubundakiler KAG sonucu non-obstrüktif koroner arter hastalığı (KAH) (<%50 darlık) olan hastalar olup, vaka grubundakiler KAG sonucu obstrüktif KAH (>%50 darlık) olan hastalar dahil edildi. Hem kontrol hem de vaka grubundaki hastalara KAG sonrası aynı hafta içerisinde stabil olduktan sonra 2D TTE ile parasternal uzun ve kısa aks görüntüler, A4C ve A2C pencerelerde standart ekokardiyografik ölçümler ile A4C ve A2C pencerelerden koroner sinüs çapı ve akım parametrelerine bakılarak her iki grup karşılaştırıldı. Bulgular: KAH tanısında TTE ile bakılan koroner sinüs çapının kontrol grubuna göre istatiksel olarak anlamlı düzeyde daha dar olduğu bulundu. KAH grubunda koroner sinüs akım parametreleri açısından anlamlı bir fark saptanmadı. Sonuç: TTE ile bakılan koroner sinüs çapının KAH erken tanısında bize yol gösterici bir parametre olabileceğine ulaştık. Bu bilginin doğruluğunun ispatı için daha büyük çalışmalarla da değerlendirilmesi gerekmektedir.en_US
dc.description.abstractObjective: To investigate the importance of coronary sinus diameter and flow parameters measured by transthoracic echocardiography in the early diagnosis of coronary artery disease. Materials and Methods: A total of 100 patients, 50 in the control group and 50 in the case group, who underwent coronary angiography (CAG) included in the study. The control group consisted of patients with non-obstructive coronary artery disease (CAD) (<50% stenosis), while those in the case group consisted of patients with obstructive CAD (>50% stenosis). Coronary sinus diameter and flow parameters obtained from Apical 4-chamber and Apikal 2-chamber windows with 2D TTE of the participants were compared. Results: Coronary sinus diameter measured by TTE in the diagnosis of CAD was found to be statistically significantly narrower than the control group. There was no significant difference in coronary sinus flow parameters in the CAD group. Conclusion: We found that the diameter of the coronary sinus measured by TTE can be a guiding parameter for the early diagnosis of CAD. In order to prove the accuracy of this information, it should be evaluated with larger studies.en_US
dc.language.isoturen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectKoroner arter hastalığıen_US
dc.subject2D transtorasik ekokardiyografien_US
dc.subjectKoroner venöz sistemen_US
dc.subjectKoroner sinüsen_US
dc.subject2D transthoracic echocardiographyen_US
dc.subjectCoronary artery diseaseen_US
dc.subjectCoronary venous systemen_US
dc.subjectCoronary sinusen_US
dc.titleEkokardiyografi ile bakılan koroner sinüs çap ve akım parametrelerinin koroner arter hastalığı ve yaygınlığı ile ilişkisinin değerlendirilmesien_US
dc.title.alternativeInvestigation of the relationship between echocardiographic coronary sinus parameters and coronary arter diseaseen_US
dc.typespecialistThesisen_US
dc.departmentFakülteler, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümüen_US
dc.institutionauthorBozkurt, Hasan
dc.relation.publicationcategoryTezen_US


Files in this item

This item appears in the following Collection(s)

Show simple item record