Advanced Search

Show simple item record

dc.contributor.authorGüneş, Mehmet
dc.contributor.authorKarakaya, Serkan
dc.contributor.authorKocaağa, Tülay
dc.contributor.authorYıldırım, Ferhat
dc.contributor.authorDilgin, Yusuf
dc.date.accessioned2024-12-18T06:44:54Z
dc.date.available2024-12-18T06:44:54Z
dc.date.issued2021en_US
dc.identifier.citationGüneş, M., Karakaya, S., Kocaağa, T., Yıldırım, F., & Dilgin, Y. (2021). Sensitive voltammetric determination of oxymetazoline hydrochloride at a disposable electrode. Monatshefte Für Chemie - Chemical Monthly, 152(12), 1505–1513. https://doi.org/10.1007/s00706-021-02862-zen_US
dc.identifier.issn0026-9247 / 1434-4475
dc.identifier.urihttps://doi.org/10.1007/s00706-021-02862-z
dc.identifier.urihttps://hdl.handle.net/20.500.12428/6751
dc.description.abstractIn this work, sensitive voltammetric determination of oxymetazoline based on its oxidation has been described at a cheap, disposable, and easily prepared pre-treated pencil graphite electrode. The recorded cyclic voltammograms proved that the oxidation response of oxymetazoline goes linearly in the concentration range between 0.25 and 500 µM. The limit of detection and sensitivity of the sensor were found as 0.08 µM and 256.0 µA mM−1 cm−2, respectively. The obtained results confirmed that applied pre-treatment procedure on pencil graphite electrode provides a high voltammetric response and sensitivity towards determination of oxymetazoline. The results (0.0496% ± 0.0003 oxymetazoline) from the real sample studies on a nasal drop (including 0.05% oxymetazoline) indicated that the designed sensor has a high potential for selective, accurate, and sensitive determination of oxymetazoline in pharmaceutical samples.en_US
dc.language.isoengen_US
dc.publisherSpringeren_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectElectrochemistryen_US
dc.subjectOxymetazolineen_US
dc.subjectPencil graphite electrodeen_US
dc.subjectPharmaceutical analysisen_US
dc.subjectSensorsen_US
dc.subjectVoltammetryen_US
dc.titleSensitive voltammetric determination of oxymetazoline hydrochloride at a disposable electrodeen_US
dc.typearticleen_US
dc.authorid-en_US
dc.authorid0000-0002-6401-3295en_US
dc.authorid0000-0002-2980-6871en_US
dc.relation.ispartofMonatshefte fur Chemieen_US
dc.departmentFakülteler, Fen Fakültesi, Kimya Bölümüen_US
dc.identifier.volume152en_US
dc.identifier.issue12en_US
dc.identifier.startpage1505en_US
dc.identifier.endpage1513en_US
dc.institutionauthorGüneş, Mehmet
dc.institutionauthorKarakaya, Serkan
dc.institutionauthorDilgin, Yusuf
dc.identifier.doi10.1007/s00706-021-02862-zen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.authorwosid-en_US
dc.authorwosidABD-2343-2020en_US
dc.authorwosidW-4565-2017en_US
dc.authorscopusid57194830184en_US
dc.authorscopusid56374132900en_US
dc.authorscopusid6507953466en_US
dc.identifier.wosqualityQ3en_US
dc.identifier.wosWOS:000714326400002en_US
dc.identifier.scopus2-s2.0-85118578850en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record