dc.contributor.author | Güneş, Mehmet | |
dc.contributor.author | Sap, Ayşe | |
dc.contributor.author | Karakaya, Serkan | |
dc.contributor.author | Yaman, Mehmet | |
dc.contributor.author | Dilgin, Yusuf | |
dc.date.accessioned | 2023-08-21T08:24:30Z | |
dc.date.available | 2023-08-21T08:24:30Z | |
dc.date.issued | 2023 | en_US |
dc.identifier.citation | Güneş, M., Şap, A., Karakaya, S., Yaman, M., & Dilgin, Y. (2023). Sensitive Amperometric Detection of Hydroxylamine at Electropolymerized Curcumin Film Coated Pencil Graphite Electrode. ChemistrySelect, 8(18). https://doi.org/10.1002/slct.202204104 | en_US |
dc.identifier.issn | 2365-6549 | |
dc.identifier.uri | https://doi.org/10.1002/slct.202204104 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12428/4508 | |
dc.description.abstract | In this study, a sensitive electrochemical method was developed for the determination of hydroxylamine (H-A) using a curcumin-modified pencil graphite electrode prepared with the electropolymerization of curcumin (PolyCurc-PGE). The PolyCurc-PGE showed a remarkable electrocatalytic response for H-A oxidation compared with bare PGE. Amperometric and cyclic voltammetric measurements were performed based on the electrocatalytic oxidation of H-A at PolyCurc-PGE. Some parameters, such as monomer concentration, pH, and cycle number during electropolymerization, were optimized to obtain the best electrochemical response of the modified electrode towards H-A. Results show that the PolyCurc-PGE gives a linear response towards H-A oxidation in the range from 0.50 mu M to 500 mu M (R-2=0.9984). In addition, the sensitivity and detection limit (LOD) of PolyCurc-PGE were found to be 5432 mu A mM(-1) cm(2) and 0.15 mu M H-A, respectively. The developed amperometric method was successfully applied to determine H-A in pharmaceutical and water samples, and acceptable results were obtained with high accuracy and precision. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | John Wiley and Sons Inc | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Amperometry | en_US |
dc.subject | Electrochemistry | en_US |
dc.subject | Electropolymerization | en_US |
dc.subject | Hydroxylamine | en_US |
dc.subject | Sensors | en_US |
dc.title | Sensitive Amperometric Detection of Hydroxylamine at Electropolymerized Curcumin Film Coated Pencil Graphite Electrode | en_US |
dc.type | article | en_US |
dc.authorid | - | en_US |
dc.authorid | 0000-0002-6401-3295 | en_US |
dc.authorid | 0000-0002-2980-6871 | en_US |
dc.relation.ispartof | ChemistrySelect | en_US |
dc.department | Fakülteler, Fen Fakültesi, Kimya Bölümü | en_US |
dc.identifier.volume | 8 | en_US |
dc.identifier.issue | 18 | en_US |
dc.institutionauthor | Güneş, Mehmet | |
dc.institutionauthor | Karakaya, Serkan | |
dc.institutionauthor | Dilgin, Yusuf | |
dc.identifier.doi | 10.1002/slct.202204104 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.authorwosid | - | en_US |
dc.authorwosid | ABD-2343-2020 | en_US |
dc.authorwosid | W-4565-2017 | en_US |
dc.authorscopusid | 57194830184 | en_US |
dc.authorscopusid | 56374132900 | en_US |
dc.authorscopusid | 6507953466 | en_US |
dc.identifier.wosquality | Q3 | en_US |
dc.identifier.wos | WOS:000985043600001 | en_US |
dc.identifier.scopus | 2-s2.0-85159137878 | en_US |