Advanced Search

Show simple item record

dc.contributor.authorKarakaya, Serkan
dc.contributor.authorDilgin, Yusuf
dc.date.accessioned2023-08-21T05:58:59Z
dc.date.available2023-08-21T05:58:59Z
dc.date.issued2023en_US
dc.identifier.citationKarakaya, S., & Dilgin, Y. (2023). The application of multi-walled carbon nanotubes modified pencil graphite electrode for voltammetric determination of favipiravir used in COVID-19 treatment. Monatshefte Für Chemie - Chemical Monthly, 154(7), 729–739. https://doi.org/10.1007/s00706-023-03082-3en_US
dc.identifier.issn0026-9247 / 1434-4475
dc.identifier.urihttps://doi.org/10.1007/s00706-023-03082-3
dc.identifier.urihttps://hdl.handle.net/20.500.12428/4476
dc.description.abstractThis study describes the first application of an improved procedure on a pencil graphite electrode decorated with functionalized multi-walled carbon nanotubes (f-MWCNTs/PGE) for the determination of the COVID-19 antiviral drug, favipiravir (FVP). The electrochemical behavior of FVP at f-MWCNTs/PGE was examined by cyclic voltammetry and differential pulse voltammetry (DPV) methods, and it was noted that the voltammetric response significantly increased with the modification of f -MWCNTs to the surface. The linear range and limit of detection from DPV studies were determined as 1-1500 mu M and 0.27 mu M, respectively. In addition, the selectivity of the method was tested toward potential interferences, which can be present in pharmaceutical and biological samples, and it was found that f-MWCNTs/PGE showed high selectivity for the determination of FVP in the presence of probable interferences. The results with high accuracies and precisions from the obtained feasibility studies also revealed that the designed procedure can be used for accurate and selective voltammetric determination of FVP in real samples.en_US
dc.language.isoengen_US
dc.publisherSpringeren_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectElectrochemistryen_US
dc.subjectFavipiraviren_US
dc.subjectFunctionalized multi-walled carbon nanotubesen_US
dc.subjectSensors voltammetryen_US
dc.titleThe application of multi-walled carbon nanotubes modified pencil graphite electrode for voltammetric determination of favipiravir used in COVID-19 treatmenten_US
dc.typearticleen_US
dc.authorid0000-0002-6401-3295en_US
dc.authorid0000-0002-2980-6871en_US
dc.relation.ispartofMonatshefte fur Chemieen_US
dc.departmentFakülteler, Fen Fakültesi, Kimya Bölümüen_US
dc.identifier.volume154en_US
dc.identifier.issue7en_US
dc.identifier.startpage729en_US
dc.identifier.endpage739en_US
dc.institutionauthorKarakaya, Serkan
dc.institutionauthorDilgin, Yusuf
dc.identifier.doi10.1007/s00706-023-03082-3en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.authorwosidABD-2343-2020en_US
dc.authorwosidW-4565-2017en_US
dc.authorscopusid56374132900en_US
dc.authorscopusid6507953466en_US
dc.identifier.wosqualityQ3en_US
dc.identifier.wosWOS:001004557200005en_US
dc.identifier.scopus2-s2.0-85161449504en_US
dc.identifier.pmidPMID: 37361695en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record